Graph: CE7-LP - Adjacent Channel Lowpass
CE7-Ch. 60/61 Lowpass
- Graph depicts abrupt roll off of hyperband "brickwall" lowpass, 1.5 MHz separates passband cut-off and stopband
- CE7-LP 60/61 pass signals up to ch.60, and removes ch. 61 and frequencies above
- Passband loss < 1.5 dB (except at knee)
- Filter size: 3.5" x 19" panel
Graph: CE7-Ch. 60/61 Lowpass
Mkr | Freq (MHz) | Attn (dB) | Channel |
1 | 439.250 | -3.12* | 60 pix |
2 Fc | 443.750 | -6.32* | 60 snd |
3 | 445.250 | -58.76 | 61 pix |
4 | 449.750 | -56.08 | 61 snd |
Pix = Picture, Snd = Sound
Order Info: model CE7-LP ch.(Fc/Fs)
Specify: Fc & Fs
Fc = cut-off channel/frequency, Fs = stopband channel/frequency
Example: CE7-LP ch.60/61, or CE7-LP 443.75/445.25